Turbo Stick Vac
OWNER’S MANUAL
Models: EP600, EP600LN
120V., 60Hz., 7.5 Amps.
EURO-PRO Operating LLC
94 Main Mill Street, Door 16
Plattsburgh, NY 12901
Tel.: 1 (800) 798-9398
Copyright © Euro-Pro Operating LLC 2006
TROUBLE SHOOTING GUIDE
IMPORTANT SAFETY INSTRUCTIONS
always be observed, including the following:
When using your SHARK TURBO STICK VAC basic safety precautions should
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
To reduce the risk of fire, electric shock, or
injury:
1. Read all instructions before using your
SHARK TURBO STICK VAC.
2. Use the system only for its intended use.
3. To protect against a risk of electric shock,
do not immerse any part of the system in
water or other liquids.
4. Never yank cord to disconnect from outlet;
instead, grasp plug and pull to disconnect.
5. Do not allow cord to touch hot surfaces.
6. Do not run appliance over cord.
7. Do not operate the system with a damaged
cord or plug, or if the appliance or any other
part of the system has been dropped or
damaged. To avoid the risk of electric
shock, do not disassemble or attempt to
repair the SHARK TURBO STICK VAC.
Return the system to EURO-PRO
1.
2.
Plug unit in firmly.
Check fuse or breaker. Replace
fuse/reset breaker.
1.
Power cord not firmly plugged into
outlet.
No power in wall outlet.
Needs servicing.
•
Do not leave the SHARK TURBO STICK
VAC plugged in when unattended. Unplug the
electrical cord when not in use and before
servicing.
VACUUM WILL
NOT OPERATE
2.
3.
4.
3.
4.
Call 1-800-798-7398.
Turn the unit off and unplug from
outlet. Allow unit to cool down,
then restart.
Thermostat has tripped.
•
•
•
Do not allow to be used as a toy. Close
attention is necessary when used by or near
children, pets or plants.
Use only as described in this manual. Use
only manufacturer’s recommended
accessories.
Do not pull cord, use cord as a handle, close
a door on cord, or pull cord around sharp
edges or corners. Keep cord away from
heated surfaces.
1.
2.
Empty and clean dust cup.
Turn unit off and unplug from
wall outlet. Remove Dust Cup
Filter and check for object(s) in
air duct and remove.
Clean or replace HEPA-Type
Filter.
Clean debris screen.
1.
2.
3.
Dust cup is full.
Unit clogged.
HEPA-Type Filter needs cleaning
or replacing.
VACUUM WILL
NOT PICK-UP OR
SUCTION POWER
IS WEAK
3.
4.
4.
Debris screen needs cleaning.
•
Use only extension cords UL-rated or cUL at
15 amperes. extension cords rated for less
amperage may overheat. Care should be
taken to arrange the cord so that the cord
cannot be pulled or tripped over.
Turn off all controls as applicable before
unplugging from electrical outlet.
Do not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
Do not handle plug or hand vacuum with wet
hands or operate without shoes.
Do not put any objects into openings. Do not
use with any opening blocked. Keep free of
dust, lint, hair and anything else that may
reduce air flow.
Operating LLC (see warranty) for
DUST ESCAPING
FROM VACUUM
1.
2.
Dust cup is full.
Dust Cup is not installed correctly.
1.
2.
Empty and clean dust cup.
Review Dust Cup instructions.
examination and repair. Incorrect re-
assembly or repair can cause a risk of
electrical shock or injury to persons when
the SHARK TURBO STICK VAC is used.
8. Close supervision is necessary for any
appliance being used by or near children.
Do not leave the system unattended while
connected.
9. Keep hair, loose clothing, fingers and all
parts of body away from opening and
moving parts.
10. Do not use to pick up flammable or
combustible liquids such as gasoline or use
in areas where they may be present.
11. Do not pick up anything that is burning or
smoking such as cigarettes, matches or hot
ashes.
•
•
•
•
1.
2.
Remove hose and/or brushes.
Remove obstruction from hose
and /or brush.
VACUUM, HOSE
OR BRUSHES
WILL NOT PICK-UP
1.
2.
Hose clogged.
Dust cup is full.
Empty and clean dust cup.
ORDERING REPLACEMENT DUST CUP FILTERS
TO ORDER REPLACEMENT HEPA-TYPE FILTERS
•
Store your appliance indoors in a cool, dry
area.
Item # XSH600
for Model EP600
Call: 1 (800) 798-7398
•
•
Keep your work area well lit.
Do not immerse the hand vacuum into water
or other liquids.
12. Use extra care when cleaning on stairs.
13. Do not use the hand vacuum without the
HEPA-TYPE dust cup filter in place.
14. This appliance is intended only for
household use. Follow all user instructions
in this manual.
•
Keep end of hose, wands and other openings
away from your face and body.
Monday to Friday 8:30 A.M. - 5:00 P.M.
Eastern Standard Time
•
•
Use only on dry surfaces.
or
Using improper voltage may result in damage
to the motor and possible injury to the user.
Correct voltage is listed on rating label.
FOR TECHNICAL SUPPORT
for Model EP600
WARNING: The power cord on this product contains lead, a chemical known to the
State of California to cause birth defects or other reproductive harm. Wash hands
after handling.
Call: 1 (800) 798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M.
Eastern Standard Time
SAVE THESE INSTRUCTIONS
Please Note:
For Household Use Only
The HEPA-TYPE Filter is washable. It should, however, be replaced every three (3)
months to ensure peak performance of your vacuum.
WARNING: To reduce the risk of electric shock, this appliance has a
polarized plug (one blade is wider than the other). This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install the
proper outlet. Do not modify the plug in any way.
Both the Pre-Motor and Post Motor Filters are washable. They should however be
replaced every three (3) months to ensure peak performance of your vacuum.
Important:
Make sure that ALL filters have been completely air dried for 24 hours before re-
installing back in the vacuum.
Rev. 01/04A
1
8
GETTING TO KNOW YOUR SHARK TURBO STICK VAC
OPERATING INSTRUCTIONS
Replacing The Dust Cup Into The
Unit
Attaching the Shoulder Strap
Use the hooks to attach the shoulder
strap to the vacuum cleaner.
• Hold the dust cup in your hand.
• Make sure that the slot on the bottom
of the cup is pointed in the same
direction as the pins in the unit (see
drawing #1).
• Slide the dust cup inside to the end of
its place in the unit (see drawing #2).
• Turn the dust cup 90° in the direction
shown in the drawing (#3) at right.
• The unit is now ready to be used
again.
Connect the dog leash swivel hooks
to the eyelets located near the top of
the unit handle and at the base of the
unit. Adjust the strap as required for
comfort.
Hook for
Shoulder
Strap
Hook for
Shoulder Strap
Warning: After extended use, the body
of the vacuum cleaner may become hot.
When using the unit with the shoulder
strap, the unit will touch the body of the
user. Therefore make sure to use the
vacuum cleaner with the strap only when
the unit is cool. If it gets too warm, allow it
to cool before continuing to use it.
Motor Thermostat
IMPORTANT: This unit is equipped
with a motor protective thermostat. If
for some reason the vacuum cleaner
should overheat, the thermostat will
automatically turn the unit off. Should
this occur:
• Push the On/Off button once.
• Disconnect the plug from the
power source.
• Check the source of overheating
problem. (i.e. clogged hose or
filter).
• If clogged hose or filter is found,
unclog the hose and replace the
filters.
• Wait at least 45 minutes before
attempting to reuse the vacuum.
• After unit has cooled down for
45 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
• If the vacuum still does not start,
contact customer service at
1-800-798-7398.
Note: To keep the vacuum cleaner
looking new, it can be wiped with a damp
cloth and a mild soap solution, then
thoroughly dried. Never use any type of
chemical cleaners as they can damage
the vacuum cleaner. When not in use,
store the vacuum cleaner in a dry, clean
place.
Technical Specifications
Voltage:
Power:
120V., 60Hz.
7.5 Amps, 900 Watts
* Note: Illustrations may differ from actual product
2
7
OPERATING INSTRUCTIONS
PRECAUTIONARY MEASURES
NOTE: Always turn off the power switch
4. Reassemble the debris screen to the
HEPA-Type filter cartridge and
replace into dust cup (container).
Ensure that the filter assembly is
completely seated inside the dust cup
(container).
5. Attach the dust cup (container) to the
vacuum.
Important: Do NOT use the HEPA-
Type filter cartridge without the debris
screen in place.
IMPORTANT: If the suction opening in the unit or the hose is BLOCKED, switch off
the vacuum cleaner and remove the blocking substance before you start the unit
again.
and unplug the electrical cord before
emptying the Dust Cup.
Cleaning & Changing the HEPA-
TYPE Dust Cup Filter
1. Do not operate the vacuum cleaner
too close to heaters, radiators or
cigarette butts.
4. When pulling out the power plug
from the wall outlet, pull the plug not
the power cord.
1. After you have emptied the dust from
the Dust Cup (container), separate
the debris screen from the HEPA-
Type filter cartridge by grasping the
debris screen with one hand and the
filter frame with the other and pull
apart.
PLEASE NOTE: The white pleated
filter material in the HEPA-TYPE Filter
will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA-
TYPE Filter
5. Do not pick up anything that is
burning or smoking such as
2. Before inserting the power plug into
the wall outlet, make sure that your
hands are dry.
cigarettes, matches or hot ashes.
Fig. A
is properly
Debris Screen
HEPA-TYPE
Filter
cleaned
Wash
once a
month or
when
suction
appears
reduced
after each use
and suction
2. Rinse the debris screen under the
faucet until clean. Allow to air dry or
dry with a clean dish towel. Do NOT
wash in dishwasher.
3. To clean the HEPA filter cartridge,
hold filter by frame flange and tap
filter on the inside wall of a dust
container (garbage can).
does not return
to 100%, then
we suggest that
the HEPA-TYPE
Filter be cleaned
vigorously until
no more dust
6. Do not use without dust cup filter in
place.
Warning: Allow 24
hours for drying before
replacing in unit.
3. Before you start vacuuming, make
sure to remove large or sharp objects
that might damage the dust cup filter.
can be removed,
then rinsed under the faucet and
allowed to air dry for 24 hours before
replacing into the vacuum. (Fig. A)
This should be done once a month
or when suction appears to be
reduced .
NOTE: If you wash the HEPA-TYPE
filter, make sure that it has
completely air dried for 24 hours
before inserting back in the
vacuum.
Ensure that you do not damage the
pleated filter material during cleaning.
Also note that discoloration occurs
during use. This does NOT affect the
filter’s performance.
Warning: Always empty the dust cup and clean the HEPA-Type dust cup
before each use and during prolonged usage. Never over fill the dust cup -
remove dirt and clean the HEPA-Type dust cup filter during prolonged usage or risk
motor damage. Make sure that the debris screen and the HEPA-TYPE filter
have completely air dried before replacing into the vacuum.
6
3
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Crevice Tool
For radiators, crevices, corners,
baseboards and
WINDING & UNWINDING THE
POWER CORD
• To wind the cord
after usage, follow
the illustration below.
• To unwind the power
cord, follow the
illustration below
but in the opposite
direction.
NOTE: Always remove the power plug
from the wall outlet before assembling or
removing accessories.
ATTACHING THE HOSE TO THE
MAIN BODY
• Press in the pin at the end of the
hose (see illustration below).
• Insert the hose into its place (see
arrow in illustration).
between cushions.
INSERTING THE 2-PIECE METAL
HANDLE INTO THE MAIN BODY
Dusting Brush
The dusting brush is used for the
furniture, venetian blinds,
books, lamp shades
and shelves.
• Push in the pin at the end of the lower
piece of the metal handle (see
illustration).
• Insert the metal handle into the hole
next to the handle. Make sure that the
slot in the handle fits correctly into the
opening. (See illustration.)
• When inserted correctly, the pin will
show in the pin hole.
• When using the vacuum, attach the
cord to the cord holder so that the
cord is out of the way when you are
vacuuming. (See below.)
Emptying The Dust Cup
• When inserted correctly, the pin should
rest in its hole.
Pin Hole
Warning: Always unplug the unit from
electrical outlet before opening the Dust
Cup (container).
Top of Retractable Handle
• Hold the dust cup in your hand.
• Turn it a complete 90° in the direction
shown in drawing #1. (Turning less than
90° will cause the dust cup to be
attached on its bottom.)
• Let the dust cup come down slightly as
shown in drawing #2.
Pin
Cord Holder
Pin
Hole
• Slide the dust cup out towards you (see
arrow in drawing #3).
• Hold the dust cup in your hand and
remove the HEPA-Type dust cup filter
(see drawing #4).
USING THE UNIT AS AN UPRIGHT
• Unwind the power cord and plug into
the 120V outlet.
• Push down in the direction of the arrow
to obtain best results on carpets or on
hard wood floors.
ON/OFF SWITCH
• The On/Off switch has two different
positions.
• Push on the "I" side to turn the
vacuum ON.
• Push on the "O" side to turn the
vacuum OFF.
• To insert the upper piece of the metal
handle, press on the pin that is on the
upper handle and insert into the lower
handle making sure that the pin comes
out of the pinhole on the lower handle.
• Empty the dust cup (see drawing #5).
NOTE: When vacuuming
deep pile carpets or
hard to vacuum
carpets, lower the
angle of the 2-piece
metal handle
(see illustration at
below) for
easier
ATTACHING THE FLOOR BRUSH
TO THE MAIN BODY
= OFF
= ON
• Push in the pin in the floor attachment
as shown in the illustration at right.
• Insert the floor brush into its location,
in the direction
of the arrow.
• When inserted
correctly, the
pin will show in
the pin hole.
maneuverability.
USING THE UNIT AS A HAND
VACUUM
• Disconnect the metal handle.
(See page 4.)
• Disconnect the floor brush.
(See page 4.)
4
Pin
Hole
• Attach the hose. (See page 4.)
• Attach the crevice tool or the dusting
brush. (See below.)
• Attach the shoulder strap.
(See page 7.)
5
5
4
|