Hand Vacuum
OWNER’S MANUAL
Model EP045
120V., 60Hz., 6.67 Amps
EURO-PRO Operating LLC
94 MAIN Mill Street, Door 16
Plattsburgh, NY 12901
Tel.: 1-866-98SHARK (1-866-987-4275)
Model EP045
IMPORTANT SAFETY INSTRUCTIONS
always be observed, including the following:
When using your SHARK Hand Vacuum, basic safety precautions should
THREE (3) YEAR LIMITED WARRANTY
To reduce the risk of fire, electric shock, or
injury:
1. Read all instructions before using your
SHARK hand vacuum.
2. Use the system only for its intended use.
3. To protect against a risk of electric shock,
do not immerse any part of the system in
water or other liquids.
4. Never yank cord to disconnect from
outlet; instead, grasp plug and pull to
disconnect.
5. Do not allow cord to touch hot surfaces.
6. Do not operate the system with a damaged
cord or plug, or if the appliance or any other
part of the system has been dropped or
damaged. To avoid the risk of electric
shock, do not disassemble or attempt to
repair the hand vacuum. Return the
system to EURO-PRO Operating LLC (see
warranty) for examination and repair.
Incorrect re-assembly or repair can cause a
risk of electrical shock or injury to persons
when the hand vacuum is used.
7. Close supervision is necessary for any
appliance being used by or near children.
Do not leave the system unattended while
connected.
8. Keep hair, loose clothing, fingers and all
parts of body away from opening and
moving parts.
EURO-PRO Operating LLC warrants this product to be free from defects in material
and workmanship for a period of three (3) years from the date of the original purchase.
This warranty applies only to normal domestic household use.
Should your appliance fail to operate properly while in use under normal household
conditions within the three (3) year warranty period, return the complete appliance and
accessories, freight prepaid to EURO-PRO Operating LLC at the address given below.
•
•
•
•
Do not leave the hand vacuum plugged in
when unattended. Unplug the electrical cord
when not in use and before servicing.
Do not allow to be used as a toy. Close
attention is necessary when used by or near
children, pets or plants.
Use only as described in this manual. Use
only manufacturer’s recommended
accessories.
Do not pull cord, use cord as a handle, close
a door on cord, or pull cord around sharp
edges or corners. Keep cord away from
heated surfaces.
In US: EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901
If the appliance is found to be defective in material or workmanship, EURO-PRO
Operating LLC will repair or replace it free of charge. Proof of purchase date and $12.95
to cover the cost of return shipping and handling must be included. *
Non-durable parts including, without limitation, dust cup filters, filters, brushes and
electrical parts which normally require replacement are specifically excluded from
warranty.
•
Use only extension cords UL-rated or cUL at
15 amperes. extension cords rated for less
amperage may overheat. Care should be
taken to arrange the cord so that the cord
cannot be pulled or tripped over.
The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or
replacement of the unit at our option. This warranty does not cover normal wear of parts
and does not apply to any unit that has been tampered with or used for commercial
purposes. This limited warranty does not cover damage caused by misuse, abuse,
negligent handling or damage due to faulty packaging or mishandling in transit. This
warranty does not cover damage or defects caused by or resulting from damages from
shipping or repairs, service or alterations to the product or any of its parts, which have
been performed by a repair person not authorized by EURO-PRO Operating LLC.
This warranty is extended to the original purchaser of the unit and excludes all other
legal and/or conventional warranties. The responsibility of EURO-PRO Operating LLC
if any, is limited to the specific obligations expressly assumed by it under the terms of
the limited warranty. In no event is EURO-PRO Operating LLC liable for incidental or
consequential damages of any nature whatsoever. Some states do not permit the
exclusion or limitation of incidental or consequential damages, so the above may not
apply to you.
•
•
•
•
Turn off all controls as applicable before
unplugging from electrical outlet.
Do not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
Do not handle plug or hand vacuum with wet
hands or operate without shoes.
Do not put any objects into openings. Do not
use with any opening blocked. Keep free of
dust, lint, hair and anything else that may
reduce air flow.
9. Do not use to pick up flammable or
combustible liquids such as gasoline or use
in areas where they may be present.
10. Do not pick up anything that is burning or
smoking such as cigarettes, matches or hot
ashes.
11. Use extra care when cleaning on stairs.
12. Do not use the hand vacuum without the
HEPA dust cup filter in place.
•
Store your appliance indoors in a cool, dry
area.
•
•
Keep your work area well lit.
Do not immerse the hand vacuum into water
or other liquids.
•
Keep end of hose and other openings away
from your face and body.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
•
•
Use only on dry surfaces.
13. This appliance is intended only for
household use. Follow all user instructions
in this manual.
Using improper voltage may result in damage
to the motor and possible injury to the user.
Correct voltage is listed on rating label.
*Important: Carefully pack item to avoid damage in shipping. Be sure to include
proof of purchase date and to attach tag to item before packing with your name,
complete address and phone number with a note giving purchase information,
model number and what you believe is the problem with item. We recommend you
insure the package (as damage in shipping is not covered by your warranty). Mark
the outside of your package “ATTENTION CUSTOMER SERVICE”. We are
constantly striving to improve our products, therefore the specifications
contained herein are subject to change without notice.
SAVE THESE INSTRUCTIONS
For Household Use Only
WARNING: To reduce the risk of electric shock, this appliance has a
polarized plug (one blade is wider than the other). This plug will fit in
a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install
the proper outlet. Do not modify the plug in any way.
Rev. 03/04
Printed in China
8
1
TROUBLE SHOOTING GUIDE
GETTING TO KNOW YOUR HAND VACUUM
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
1. Power cord not firmly
plugged into outlet.
2. No power in wall outlet.
3. Needs servicing.
4. Thermostat has
tripped.
1. Plug unit in firmly.
2. Check fuse or breaker. Replace
fuse/reset breaker.
HAND VACUUM
WILL NOT
OPERATE
3. Call 1-800-798-7398.
4. Turn the unit off and unplug from
outlet. Allow to cool.
1. Empty dust cup – (see pages 5/6).
2. Turn unit off and unplug from wall
outlet. Remove HEPA Dust Cup
Filter and check for object(s) in air
duct and remove.
3. Clean or replace HEPA Dust Cup
Filter. (see pages 5/6)
1. Dust cup is full.
2. Unit clogged.
3. HEPA Dust Cup Filter
needs cleaning or
replacing.
HAND VACUUM
WILL NOT PICK-UP
OR SUCTION
POWER IS WEAK
TURBO BRUSH
DOES NOT
ROTATE OR
ROTATES
1. Rotating brush or
elbow obstructed.
2. Hose obstructed.
3. HEPA dust cup filter
clogged.
1. Clear obstructions. (see page 5.)
2. Clear obstruction.
3. Clean HEPA dust cup filter. (See
pages 5/6.)
SLOWLY
1. Dust cup is full.
2. HEPA Dust Cup Filter
is not installed
1. Empty dust cup.
DUST ESCAPING
FROM HAND
VACUUM
2. Review HEPA Dust Cup Filter
instructions. (see pages 5/6)
3. Replace HEPA dust cup filter. (see
pages 5/6)
correctly.
Debris Screen
HEPA Filter
3. There is a puncture or
hole in HEPA Dust Cup
Filter.
HAND VACUUM
HOSE OR
BRUSHES WILL
NOT PICK-UP
1. Remove hose and/or bushes.
Remove obstruction from hose.
2. Empty and clean dust cup.
1. Hose clogged.
2. Dust cup is full.
ORDERING REPLACEMENT FILTERS
12
TO ORDER REPLACEMENT HEPA FILTERS
FOR MODEL EP045
1. On/Off Switch
7. Flexible Hose
8. Crevice Brush
9. Oval Dusting Brush
10. Pet Hair Removal Attachment
11. Shoulder Strap
12. HEPA Filter
13. Air Driven Turbo Brush
2. Dust Cup (Container)
3. Dust Cup Release Button
4. Exhaust Filter Cover (x2)
5. Handle
Style # XSH045 – HEPA Filter Only
Call:
1-866-98SHARK (1-866-987-4275)
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
6. Suction Hole
or
FOR TECHNICAL SUPPORT
for Models EP045
Call:
1 (800) 798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Technical Specifications
Please Note: After each Use - Always remove the Filter Debris Screen from the HEPA Dust
Cup Filter, then vigorously “TapClean” HEPA Filter until no more dust can be removed. Filter
should be rinsed and completely dried at least once a month or when suction appears
reduced.
Voltage:
Power:
120V., 60Hz.
6.67 Amps, 800 Watts
To wash your HEPA Dust Cup Filter, hold filter cartridge by frame flange and rinse under a
tap until all observable dirt has been removed. Some discoloration of the HEPA filter material
may occur, this is normal and will not affect the filter's performance. When finished, shake off
excess water. Do NOT wash in dishwasher.
Illustrations may differ from actual product.
It is important that when you wash the HEPA dust cup filter, you allow it to dry
COMPLETELY before using again. We recommend 24 hours to air dry. DO NOT DRY IN
DRYER.
2
7
OPERATING INSTRUCTIONS cont.
PRECAUTIONARY MEASURES
5. Vigorously “TapClean”
the HEPA Dust Cup
Filter on a hard
surface until no more
dust is observed
falling out from
between the pleats of
the filter. (Fig. 6)
Changing & Cleaning the Exhaust
Filters
Important: If the suction opening in the unit or the hose becomes blocked, switch off
the vacuum cleaner and remove the blocking substance before you start
the unit again.
Fig. 6
The exhaust filters are washable filters
but should be replaced every three (3)
months depending on usage.
• Remove the exhaust filter covers from
the sides of the unit. (See illustration
below.)
5. When pulling out the power plug
from the wall outlet, pull the plug
not the power cord.
1. Do not operate the vacuum
cleaner to close too heaters,
or radiators.
Exhaust
Filter Cover
Exhaust
Filter
6. “TapClean” the Debris
Screen or rinse under
a faucet until clean.
(Fig. 7) Remember
that the Debris Screen
must be completely
air dried for 24 hours
before reinstalling
Fig. 7
Debris
Screen
in the vacuum.
6. Do not pick up anything that is
burning or smoking such as
Exhaus
t Filter
7. Replace the Debris Screen on the
HEPA Dust Cup Filter and reinstall
filter assembly in the vacuum. (not
shown)
PLEASE NOTE: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Dust Cup Filter
cigarettes, matches or hot ashes.
2. Before inserting the power plug
into the wall outlet, make sure that
your hands are dry.
Exhaust
Filter
Cover
7. Do not use without HEPA dust cup
filter in place.
• Rinse the exhaust filters in lukewarm
water and air dry the filters completely.
Do not use a washing machine to rinse
the filters. Do not use a hair dryer to
dry them. Air dry only for 24 hours.
Never operate the vacuum
8. Before you start vacuuming,
make sure to remove large or
sharp objects that might
is properly
"TapCleaned”
without the exhaust filters in
place.
damage the vacuum.
Fig. A
3. Do not vacuum any liquids.
after each use
and suction
does not return
to 100%, then
• When the filters are dry,
replace them into the
exhaust filter covers and
replace the filter covers on
Wash once a
month or when
suction
appears
4. Keep hair, loose clothing, fingers,
feet and all parts of body away from
openings.
reduced.
we suggest that
the HEPA filter
be “TapCleaned”
vigorously until no
more dust can be removed, then
rinsed under the faucet and allowed to
air dry for 24 hours before refitting into
the vacuum. (Fig. A) Wash once a
month or when suction appears
reduced.
the unit.
Warning: Allow 24
hours for drying before
replacing in unit.
• A severely soiled or clogged
filter should be thoroughly washed with
fresh tepid water. A mild detergent
can be used if required.
Please Note: The HEPA Dust Cup Filter
is washable. It should, however, be
replaced every six (6) months to ensure
peak performance of your vacuum.
The Exhaust filters are washable. They
should however be replaced every six (6)
months to ensure peak performance of
your vacuum.
CAUTION: The suction hole must
be open, free of any obstructions at
all times. Otherwise, the motor will
overheat and could become damaged.
Important: Make sure that ALL filters are
completely dry before re-installing back in
the hand vacuum.
Important: All filters should be checked
regularly for signs of damage, preferably
after each cleaning task. The filters must
be replaced immediately if they become
damaged. Always disconnect the vacuum
from the electrical outlet when checking
the filters.
3
6
OPERATING INSTRUCTIONS cont.
OPERATING INSTRUCTIONS
Warning: Always unplug from
electrical outlet before opening the
dust cup (container).
Cleaning & Changing the
HEPA Dust Cup Filter
Warning: Always unplug the unit
from electrical outlet before opening
the Dust Cup (container).
Important: Do NOT use the HEPA filter
cartridge without the debris screen in
place.
Warning: After each Use - Always
remove the Filter Debris Screen
from the HEPA Dust Cup Filter, then
vigorously “TapClean” HEPA Filter until
no more dust can be removed.
Using The Unit With Air
Driven Turbo Brush
The efficiency of your air driven turbo
brush depends on the bristle brush
rotating at high speed. Strong air suction
is needed to accomplish this. In order to
ensure that maximum air suction is
maintained, please read the following
instructions:
4. To use the flexible hose, push
the end of the hose into the
suction hole, then attach the
desired accessory to the other
end of the flexible hose,
Note: HEPA dust cup filter must be used
when operating the hand vacuum.
as shown below.
Using The Unit As A Hand
Vacuum
1. To open the dust
cup (container),
1. Empty the dust cup frequently.
2. Always "TAPCLEAN" the HEPA dust
cup filter when emptying the dust cup
container.
3. Ensure that the rotating brush is kept
free of hair and string which may
accumulate and decrease brush
performance.
4. Keep Air Driven Turbo Brush turbine
free of dirt and foreign matter. (See
illustration below for cleaning
instructions.)
push the dust cup
release button and
pull out the dust
cup. Verify that the
HEPA dust cup filter is inside
(see illustration below), then re-
attach the dust cup (container) to
the hand vacuum.
How To Operate Your
Hand Vacuum
1. Hold the hand vacuum firmly in your
hand by the Handle.
2. Push the On/Off Power Switch to
“On” position.
3. Start vacuuming.
IMPORTANT, Please Note : The
“TapClean” HEPA Dust Cup Filter &
Debris Screen will stop most of the tiniest
dust particles and airborne allergens from
re-entering the air you breathe. In fact it
stops 99.97% of all particles as small as
0.3 microns - many times smaller than a
human hair!!! Because of this incredible
filtration performance, the HEPA Dust Cup
Filter will quickly accumulate, inside the
white filter folds, many fine dust particles
that are difficult to see but which will
eventually block or reduce your suction
power - if not cleaned properly. Clean the
HEPA Filter and Debris Screen after each
use as described in this section.
CAUTION: The Hand Vacuum is
a very powerful unit. Make sure
that you hold it firmly, otherwise it
can slip out of your hand and cause
injury.
Cleaning Air Driven Turbo
2. To use the Hand Vacuum with the
shoulder strap, attach it to the unit as
shown below.
Brush
Tilt
Important: This unit is equipped with a
motor protective thermostat. If for some
reason the vacuum cleaner should
overheat, the thermostat will
automatically turn the unit off. Should
this occur:
• Push the On/Off button once.
• Disconnect the plug from the
power source.
• Check the source of overheating
problem. (i.e. clogged hose or
filter)
• If clogged hose or filter is found,
unclog the hose and replace the
filters.
• Wait at least 45 minutes before
attempting to reuse the vacuum.
• After unit has cooled down for
45 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
• If the vacuum still does not start,
contact customer service at
1 (800) 798-7398.
Upwards
Locking
Latch
1. To open the Dust Cup (container),
push button and detach the Dust
Cup (container ). (Fig. 2)
2. Pull out the HEPA Dust Cup Filter.
(Fig. 3)
3. To attach the oval dusting brush,
crevice brush or the pet hair
removal attachment to the Hand
Vacuum, push attachment into the
suction hole, as shown below.
Turbine
Wheel
Fig. 1
From time to time, the turbine of your
turbo brush will require cleaning. To do
this:
1. Remove the turbo brush from the hose
or unit.
2. Turn turbo brush over and open the
hinged cover to access the turbine
wheel. (see Fig. 1)
3. There may be some dust, lint, hair, etc
on the turbine wheel. Remove as much
of this as possible.
Fig. 3
Fig. 2
3. Empty the dust from
the Dust Cup
(container). (Fig. 4)
4. Separate the debris
screen from the
HEPA filter cartridge
by grasping the
debris screen with
Fig. 4
one hand and the filter frame with the
other and pull apart. (Fig. 5)
4. You may also use the unit’s hose to
remove any additional debris from the
turbine.
NOTE: The pet hair removal
attachment is for use on upholstery,
drapes and other fabric surfaces to
remove lint, pet hair, etc. THE PET
HAIR REMOVAL ATTACHMENT IS
NOT INTENDED TO BE USED AS A
PET GROOMING DEVICE.
Debris
Screen
HEPA Filter
Fig. 5
4
5
|