SPECIAL WARNING
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
CLEARANCES AND DIMENSIONS
For SAFETY CONSIDERATIONS do not install drawer in any combustible cabinetry, which is not in
accord with the stated clearances and dimensions on pages 2 and 3. See Figures 1 and 2.
UNPACKING YOUR MICROWAVE DRAWER
IMPORTANT NOTES
2
2
2
2
3
3
ELECTRICAL OUTLET
4
4
4
4
4
GROUNDING INSTRUCTIONS
DRAWER INSTALLATION
IMPORTANT SAFETY INSTRUCTIONS
CLEARANCES AND DIMENSIONS
MICROWAVE DRAWER MEASUREMENTS
ANTI-TIP BLOCK
MODEL AND SERIAL NUMBER LOCATION
CARE, CLEANING AND MAINTENANCE
INSTALLATION MANUAL
electrical outlet
location
6"
2x4 Anti-
Tip block
MICROWAVE DRAWER MEASUREMENTS
3 1/2"
5"
4"
14 3/4"
to bottom
28 7/16"
opening
allow 1/4"
of Anti-Tip
overlap
allow 3/4"
overlap
block
14 3/4"
opening
23 1/2"
min depth
allow 3/4"
overlap
36"
countertop
height
floor must
support
100 lbs.
allow 7/16"
overlap
84"
wall
cabinet
19"
to top of floor
optional wall oven
cutout illustrated
in sketch
NOTE: Open Top
Cabinet illustrated
30" *
cabinet min.
electrical outlet
location
(6")
Figure 1
2x4 Anti-Tip block
3 1/2"
5"
Figures 1 and 2 contain many Microwave Drawer measurements
for reference when planning the drawerʼs location.
2" minimum
4"
28 7/16"
opening
14 3/4"
to bottom
of Anti-Tip
block
4 11/16"
28 1/8"
allow 1/4"
overlap
allow 3/4"
overlap
2"
14 3/4"
opening
23 1/2"
allow 3/4"
overlap
min depth
floor must
support 100 lbs.
allow 7/16"
overlap
15 13/32"
14 19/32"
15"
auto drawer
opening
*19"
to top of floor
(recommended)
23 3/8"
30"
cabinet min.
Figure 2
Figure 3
1 13/16"
door thickness
30"
NORMAL INSTALLATION STEPS
ANTI-TIP BLOCK INSTALLATION INSTRUCTIONS
ANTI-TIP BLOCK
To reduce the risk of tipping of the drawer, the Anti-Tip block
must be properly installed located 14 3/4-inches above the floor on
which the Microwave Drawer will sit. The 6-inch 2 x 4 Anti-Tip
block must be provided by the installer. See Figures 1, 2 and 4.
The Anti-Tip block prevents serious injury that might result from
spilled hot liquids.
(6")
2x4 Anti-
Tip block
If the Microwave Drawer is ever moved to a different location, the
Anti-Tip block must also be moved and installed. When installed
to the wall, make sure that the screws completely penetrate the
dry wall and are secured in wood or metal so that the block is
totally stable. When fastening, be sure that the screws do not
penetrate electrical wiring or plumbing.
Figure 4
3
INSTALLATION MANUAL
DRAWER INSTALLATION
ELECTRICAL OUTLET
electrical outlet location
5"
4"
Figure 6
Figure 5
Parts Supplied
4 Screws
1. Place the drawer adjacent to the wall or
cabinet opening. Plug the power supply cord
into the electrical outlet.
The electrical requirements are a 120 volt 60 Hz, AC only, 15
amp. or more protected electrical supply. It is recommended that
a separate circuit serving only this appliance be provided.
2. Carefully guide the drawer into the prepared
opening. Avoid pinching the cord between
The drawer is equipped with a 3-prong grounding plug. It must
be plugged into a wall receptacle that is properly installed and
grounded. Should you only have a 2-prong outlet, have a qualified
electrician install a correct wall receptacle.
3. Slide the drawer all the way until the mounting flange is flush
with the face of the cabinet.
If you have any questions about the grounding or electrical
instructions, consult a qualified electrician or service person.
4. Secure the drawer with the 4 screws supplied. See Figure 6.
MODEL AND SERIAL NUMBER LOCATION
The name plate, including model and serial number, is located
on the faceplate behind the Microwave Drawer front.
GROUNDING INSTRUCTIONS
This appliance must be grounded. The Microwave Drawer is
equipped with a cord having a grounding wire with a grounding
plug. It must be plugged into a wall receptacle that is properly
installed and grounded in accordance with the National
CARE, CLEANING AND MAINTENANCE
Refer to the Operation Manual for cleaning instructions.
Permanent and Correct Installation
of an electrical short circuit,
grounding reduces risk of
electric shock by providing
an escape wire for the electric
3-Prong Plug
BEFORE YOU CALL FOR SERVICE
Read the BEFORE YOU CALL and operating instruction sections
in your Operation Manual. It may save you time and expense.
The list includes common occurrences that are not the result of
defective workmanship or materials in this range.
Grounding Pin
– Improper use
of the grounding plug can result
in a risk of electric shock.
3-Prong Receptacle
Ground Receptacle Box
Refer to the warranty in your Operation Manual for Sharpʼs
toll-free service number and address. Please call or write if you
have inquiries about your microwave product and/or need to
order parts.
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
PRINTED IN USA
TINSEB417MRR0
|